Download BulkGas 1500 Brochure 
The BulkGas™1500 Gas Delivery System is representative of SDC's continuous drive and commitment to providing the industry’s safest and most reliable gas equipment available.
Mass customization and modular design concepts of the gas panels, controls architecture and cabinet enclosure have been combined to widen the product configuration
spectrum and greatly increase user flexibility.
From the Fab to the Lab to the University, SDC sets its itself apart as the clear choice for value in today’s budget conscious environment.
Please note that manual and/or semi-automated systems like the BulkGas™ are not recommend for use in ALL applications. SDC recommends that FULLY AUTOMATED SYSTEMS be used for toxics, corrosives, pyrophorics and other highly hazardous gases/ liquefied gases.
Standard Configurations:
- 1-cyl, [1-process]
- 2-cyl, [1-process, 1-purge]
- 2-cyl, [2-process]
- 1-cyl, [2-process, 1-purge]
- Independent out or autoswitchover
Standard Controls / Features:
- PLC control of all critical functions
- Bright 10.4" color touch screen interface
- Proven auto-sequenced routines for all aspects of operation & maintenance
- User settable limits for all process and alarm parameters
- Exhaust pressure monitor
- On-screen warning, alarms, prompting and instructions
- Emergency Off [EMO]
- EMO & EGO inputs
- Alarm outputs
- Multi-level password protection
- Diagnostics screen
- Valve cycle count screen
- Z-Purge ready for CLASS I DIV II
Process Panel Features:
- Ultra-High-Purity [UHP] 316L or VAR construction
- Surface finish of 10Ra avg. or better
- Springless diaphragm valves
- Process regulator
- Precision pressure transducers
- Excess flow sensor
- Gas Vacuum assisted purging
- UHP orbitally welded with strategic VCR® breaks
- Helium leak tested to 1 x 10-9 atm*cc/s
- CLASS 100 / CLASS 10 cleanroom assembled
- Cylinder scales [with LCD digital indicator]
- CGA torque wrenches
Process Panel Features:
- SEMI® S2
- CE® mark
- ASME Section IX
- Factory Mutual®
- ASMNFPA® 79, 496, 70 [NEC]
- UL®
EXHAUST SPECIFICATIONS/REQUIREMENTS |
| CDA |
adjustable to 90 psig
|
1 slm max. |
| Purge N2 |
adjustable to 85 psig |
85 slm max. |
| Venturi N2 |
adjustable to 60 psig |
30 slm max. |
| Process Vent |
>1.0" WC |
100 slm |
| Power |
110V, 3A |
N/A |
| Sprinkler |
30 psig |
31 gpm |
| Exhaust |
>0.20 H2O |
300 scfm |
*Depending on the specific gas and the combined volume, this flow may be higher. |