Download FlexGas Brochure 
The FlexGas™ Gas Cabinet is designed to cover a wide range of cylinder gas delivery applications. In its simplest form, the FlexGas™ Gas Cabinet houses 1, 2, 3 or 4 gases, and includes a high purity, manual gas panel for each gas. Modular FlexGas™ Panels are available in 1, 2, 3, 4 and 6-Valve designs. Each panel may be tailored to the specific gas and application.
With the addition of the optional FlexPowr™ Controller, the FlexGas™ Cabinet can support a myriad of automated ALARM and panel SHUTDOWN options such as: Auto-Switchover, Excess Flow Sensors, Low Cylinder Pressure Alarms, High Delivery Pressure Alarms, Gas Leak Sensors, Scales and more! The FlexPowr™ Controller can support up to eight (8) user-settable alarm inputs and eight (8) user-settable alarm outputs. EMO slambutton and Exhaust Pressure Sensor are included with the FlexPowr™ Controller option.
FlexGas™ makes it easy to meet your exact gas delivery needs. Our modular design concept allows you to use a building-block method to configure a gas cabinet to your specifications.
Begin by choosing one of several cylinder enclosure configurations. Then proceed to the gas panel level by selecting the gas panel purity. From the standard 3-Valve UHP panel, you can choose to add PURGE capability (4-Valve) or PURGE/EVAC capability (6-Valve).
Add safety and peace-of-mind by purchasing the optional FlexPowr™ Controller. Simply select which panels you want to shutdown on ALARM, and they will be fi tted with a normally-closed ESO Valve for automatic shutdown. The FlexPowr Controller supports up to 4 dry contact alarm inputs. Exhaust pressure switch, gas leak detection, andn UVIR are just some of the optional controls components available to prompt shutdown.
Cylinder Cabinets
Standard Configurations:
- 1-cyl, [1-process]
- 2-cyl, [1-process, 1-purge]
- 2-cyl, [2-process]
- 2-cyl [2-process, *Purge SideCar™]
- 3-cyl, [3-process]
- 3-cyl, [2-process, 1-purge]
- 3-cyl [3-process, *purge SideCar]
* Purge SideCar is an external, integrated purge cylinder
Gas Panels/Manifold Purity:
Standard configurations
- UHP construction: orbitally welded/VCR® 316L SS or VIM/VAR
- UHP grade regulator (non-tied diaphragm standard)
- IUHP grade diaphragm valves (20 Ra standard)
HP Gas Panel Standard Configurations:
- 3-Valve design [HP vent]
- 4-Valve design [adds PURGE]
- 6-Valve design [adds EVAC]
UHP Gas Panels Options:
- 10 Ra surface finish
- Dual stage regulators
- Outlet filters (0.003 um)
- DISS cylinder fittings
Industrial Gas Panels Standard Configurations:
- 3-Valve process gas panel [adds HP vent, 1-Valve is standard]
Optional FlexPowr™ Controller:
- Automatic shutdown of process gas panels
- Up to 8 user-definable alarms
- Up to 8 user-definable outputs
- Audible/visible alarm indication
- EMO button
- Multilevel password protection
FlexPowr™ Control Components:
- Exhaust pressure switch
- HI cylinder pressure switch
- HI delivery pressure switch
- Integrated gas leak detection
- UVIR detection
- Excess flow sensor
Other Equipment Options:
- Adjustable cylinder shelves
- Restrictive flow orifices
- Cylinder scales
- CGA torque wrenches
Dimensions*
- 1-cyl: 18"W x 72"H x 19"D
- 2-cyl: 24"W x 72"H x 19"D
- 3-cyl: 36"W x 72"H x 19"D
* Add 8" to height for optional FlexPowr™ controller.
FACILITIES REQUIREMENTS |
| 1Pneumatic Supply |
Adjustable to 90 psig |
1 slm max. |
| 2Process Purge |
Adjustable to 80 psig |
30 slm max. |
| 3Vacuum Drive |
Adjustable to 85 psig |
85 slm max. |
| 4Process Vent |
>1.0"WC |
100 slm |
| 1Power |
115V/3A |
N/A |
| Sprinkler |
30 psig |
31 gpm |
| 5Exhaust |
>0.15" WC |
300 scfm(2-cyl) |
|
>0.15" WC |
450 scfm (3-cyl) |
1Required with optional FlexPowr™ Controller
2Required with 4-Valve, 6-Valve gas panel configurations
3Required with 6-Valve gas panel configurations
4Required with 3, 4, 6 -Valve gas panel configurations |
Please note that manual and/or semi-automated systems like the FlexGas™ are not recommended for use in all applications. SDC recommends that FULLY AUTOMATED SYSTEMS be used for toxics, corrosives, pyrophorics, and other highly hazardous gases/liquified gases. |

2-Cylinder Model with UHP Gas Panels and optional FlexPowr™ Controller |